As an example in an attic that is 30 feet by 20 feet you would have 600 square feet of floor area.
Estimating ventilation requirements for attic.
Hence you would need two square feet 600 300 of attic ventilation.
Measure the length and width of the attic floor space to be ventilated.
In order to facilitate this exchange of warm and cool air the general rule of thumb suggests installing at least 1 sq.
A normal metal pot vent produces only 50 squares inches of free net area.
The federal housing authority fha and the urban development hud have established minimum requirements for attic ventilation.
The calculations before indicated that we needed 2 square feet of ridge or upper roof ventilation.
Ventilation of attic spaces is required by most building codes as well as by roofing material manufacturers and the national roofing contractors association nrca.
According to their requirements you should have 1 square foot of attic ventilation per 300 sq ft of attic floor space.
Let owens corning roofing help you calculate exactly how much ventilation you will need for a healthy and balanced attic with our 4 step ventilation calculator.
Enter square footage calculate or enter the square footage of the attic or area to be vented.
Before we explore how to ventilate an attic space it is prudent to understand how much ventilation is needed.
Of vent for every 300 sq.
Regarding attic ventilation nrca recommends designers provide at least 1 square foot of nfva for every 150 square feet of attic space 1 150 ventilation ratio measured at the attic floor level ceiling.
According to the national roofing contractors association nrca a power vent with an airflow rate of 1 0 cubic foot per minute per square foot of attic space measured at the attic floor is generally considered to be equivalent to a 1 150 ventilation ratio.
If your roof is 1200 sq ft soffit floor space you will need 4 sq feet of roof ventilation.
For large volume attics such as where roof slopes are greater than 8 12 designers also should consider increasing.
Ventilation can be accomplished using various products and techniques.
So we would need at least six metal vents in addition to the lower soffit ventilation to meet minimum ventilation requirements.
According to the fha federal housing administration us for every 300 square feet of attic floor area you should have at minimum one square foot ventilation.
There should also be a 50 50 balance of attic venting and roof venting.