Exits must be kept clear of obstacles at all times.
Fire exit door requirements nz.
Revoked on 1 july 2018 by regulation 36 of the fire and emergency new zealand fire safety evacuation procedures and evacuation schemes regulations 2018 li 2018 96.
Ceilings of exit routes must be at least 7 feet 6 inches high.
Self closing the nzbc requires a fire door set to be self closing.
Seals edges of a fire door have fire rated seals.
Self latching the nzbc requires a fire door set to be self latching.
The new fire and emergency new zealand act 2017 and the fire and emergency nz fire safety evacuation procedures and evacuation schemes regulations 2018 both describe.
There are also additional requirements where the door is the final exit point of a building.
The same requirements as above will apply to a fire exit door.
The door should open in the direction of evacuation.
The new zealand building code nzbc includes requirements for fire doors in the acceptable solutions c as1 to c as6.
The acceptable solutions require fire doors to comply with nzs 4520 fire resistant door sets ref.
There should be no locks or catches.
An occupier in relation to a building includes any person lawfully entitled to be in the.
An exit is permitted to have only those openings necessary to allow access to the exit from occupied areas of the workplace or to the exit discharge.
Key locks on exit doors in a commercial building retail and food outlets.
Exit doors must not be locked barred or blocked there can be a management system in place where doors need to be locked due to people being under care or supervision.
An opening into an exit must be protected by a self closing fire door that remains closed or automatically closes in an emergency upon the sounding of a fire alarm or employee alarm system.
Exit routes must support the maximum permitted occupant load for each floor served and the capacity of an exit route may not decrease in the direction of exit route travel to the exit discharge.
Smoke control and fire stop doors must not be kept open unless done so in a way that complies with the building code.
This access to exit requirements seeks to minimize occupants exposure to these and other hazards.
We work closely with specifiers and builders to ensure new zealand construction projects get the fire doors they need to satisfy regulations aesthetic considerations and budget constraints.
Fire doors are assigned a fire resistance rating frr from the results of fire testing to as1530 4.
Fire safety and evacuation of buildings regulations 2006.
The nfpa emergency exit door requirements code states there is a maximum travel distance allowed to find an exit.
Anatomy of a fire door.
An exit access must be at least 28 inches wide at all points.